SD 60 Syringe Infusion Pump
Technical Specification
General:
Loading |
Front |
Automatically Detected Syringe Sizes |
All brands, User selectable major brands and manual calibration of local brands |
Models |
Normal, KVO, Bodyweight mode & patient control Anaelgesia |
Flowrate Range |
10 m1=0.1 ml/hr-300.0 ml/hr, |
Least Count In Flowrate |
0.1ml/syringe |
Syringe Size Auto-Detection |
Yes |
Drug Name |
24 drug library |
Alarms |
Near Empty, Over Occlusion, Syringe Dislocation Malfunction, Low Batt, Low Batt Shutting down |
Occlusion |
a. Low= 300+/-100mm Hg (40.7 +/-13.3 KPa) b. Medium = 500 +/-100mm Hg (66.7+/-13.3 KPa) c. High = 800+/-200 mm Hg (106.7+/-26.7 KPa) |
Total Volume Range |
0.1 m1-9999 ml |
Bolus |
Auto & Manual a. 1000 ml/hr for 50/60 ml syringe b. 300 ml/hr for 10 ml syringe c. 400 ml/hr for 20 ml syringe |
Drug Delivery chart |
Starting date & time, Ending date& time, drug name, Infusion rate set |
Physical Characteristics:
Dimensions |
(262x 130x 125) in mm |
Weight |
2.4 Kg |
Display:
Type |
Color TFT display |
Size |
2.8" Diagonally |
Resolution |
240 (RGB) x 320 Pixels |
Electrical:
Power Input |
110-260VAC, 47-63 Hz |
Inbuilt Battery Type |
Li-ion |
Battery Rating |
7.4V/2200 mA |
Charging Time |
6 Hours |
Operating Time |
4 Hours |
Power Consumption |
15 Watt |
Environmental Conditions:
Operating Temperature |
0 to 45°C |
Storage Temperature |
-10 C to 55°C |
Operating & Storage Pressure |
86-106 KPa |
Operating & Storage Relative Humidity |
20 -90 % Non condensing |
Estimated Delivery Time:_5 to 7 Working Days
VARIANT | SELLER | PRICE | QUANTITY |
---|
Brand | MAESTROS ELECTRONICS |
SD 60 Syringe Infusion Pump
Technical Specification
General:
Loading |
Front |
Automatically Detected Syringe Sizes |
All brands, User selectable major brands and manual calibration of local brands |
Models |
Normal, KVO, Bodyweight mode & patient control Anaelgesia |
Flowrate Range |
10 m1=0.1 ml/hr-300.0 ml/hr, |
Least Count In Flowrate |
0.1ml/syringe |
Syringe Size Auto-Detection |
Yes |
Drug Name |
24 drug library |
Alarms |
Near Empty, Over Occlusion, Syringe Dislocation Malfunction, Low Batt, Low Batt Shutting down |
Occlusion |
a. Low= 300+/-100mm Hg (40.7 +/-13.3 KPa) b. Medium = 500 +/-100mm Hg (66.7+/-13.3 KPa) c. High = 800+/-200 mm Hg (106.7+/-26.7 KPa) |
Total Volume Range |
0.1 m1-9999 ml |
Bolus |
Auto & Manual a. 1000 ml/hr for 50/60 ml syringe b. 300 ml/hr for 10 ml syringe c. 400 ml/hr for 20 ml syringe |
Drug Delivery chart |
Starting date & time, Ending date& time, drug name, Infusion rate set |
Physical Characteristics:
Dimensions |
(262x 130x 125) in mm |
Weight |
2.4 Kg |
Display:
Type |
Color TFT display |
Size |
2.8" Diagonally |
Resolution |
240 (RGB) x 320 Pixels |
Electrical:
Power Input |
110-260VAC, 47-63 Hz |
Inbuilt Battery Type |
Li-ion |
Battery Rating |
7.4V/2200 mA |
Charging Time |
6 Hours |
Operating Time |
4 Hours |
Power Consumption |
15 Watt |
Environmental Conditions:
Operating Temperature |
0 to 45°C |
Storage Temperature |
-10 C to 55°C |
Operating & Storage Pressure |
86-106 KPa |
Operating & Storage Relative Humidity |
20 -90 % Non condensing |