VOLUMETRIC PUMP ACURA V1
Acura V1 is Volumetric pump with color display, suitable for critical care and general infusion applications. Flow rate starts from 0.1ml/hr & compatible with all brands of infusion sets.
Infusion Modes: Rate Mode, Time Mode, Weight Mode, Stage Mode, Drip Rate Mode.
Features
Color Display
High definition 3.2” Color TFT display with user friendly interface
Multiple Infusion Modes
In-built Flow rate, Time/volume, Dosage/Weight, Infusion modes
Double CPU
Double CPU ensures safety and reliability of infusion
Bolus Modes
Dual bolus: Automatic and Manual along with Anti-Bolus function.
Device Memory
2000 history records and last configuration memory
Accurate Infusion
Precise control of the infusion rate and volume with Particular stage infusion mode
Automatic IV Set Calibration
Calibrated for all standard IV Infusion sets
Pressure Detection
3 level occlusion sensitivities setting (programmable) with picture representation
Alarms
Audio and visual alarms for alerts
Fixing Clamp
Vertical & Horizontal rotatable fixation clamp
Technical Specifications
Display |
3.2 inch Color TFT (240X320 Pixels) |
IV Sets |
Standard IV sets of 20d/ml and 60d/ml, with diameter 3.4-4.5mm |
Infusion Modes |
Rate Mode, Time Mode, Drug/ Weight Mode, Drip Rate Mode(optional) |
Infusion Accuracy |
≤± 5 % (after calibration) |
Volume Limit |
1-9999 ml |
Flow Rate Range |
0.1 ml/hr-1200ml/hr (20d/ml IV set) |
0.1 ml/hr-1200ml/hr (20d/ml IV set) |
|
BOLUS |
Default 600ml/h, Values adjustable within 10-1200ml/hr (20d/ml IV set) |
Default 150ml/h ,Values adjustable within 10-150ml/hr (60d/ml IV set) |
|
BOLUS Accuracy |
≤± 5 % (after calibration) |
Purge Rate |
600ml/hr (20d/ml IV set) |
150ml/hr (60d/ml IV set) |
|
KVO |
0.1-10ml/hr (after infusion) |
Occlusion Level |
3-level Sensitivities Setting |
Bubble detection |
Ultrasonic with 3-level sensitivities setting, working frequency: 2MHz±5% |
Effective bubble detection volume:≥0.025ml |
|
Audio & Visual Alarm |
Door open, AIR in Line, Occlusion, No operation, Power OFF, Low Battery, Battery Err, Battery Lost, AC Lost, Sensor Err, Motor Err, Circuit Err.,COM. Err, Overflowing etc. |
Power Supply |
100V-240V AC,50Hz/60Hz |
Battery Type |
Internal rechargeable Ni-MH DC12V 2000mAh |
Battery Backup |
4 hours at 25ml/hr after fully recharged |
Classification |
Class I, CF, IPX2 |
Dimensions |
167mm(L) X 125mm(B) X 115mm(H) ( handgrip and clamp excluded) |
Weight |
1.8Kg Approx |
Operational Conditions |
Temperature: +5˚C - +40˚C |
Relative Humidity ≤80% |
|
Atmospheric Pressure 70KPa - 106Kpa |
|
Storage & Transportation Conditions |
Temperature: -22˚C - +55˚C |
Relative Humidity : 10% - 90% |
|
Atmospheric Pressure 70KPa - 106Kpa |
Estimated Delivery Time:_5 to 7 Working Days
VARIANT | SELLER | PRICE | QUANTITY |
---|
Brand | BPL |
VOLUMETRIC PUMP ACURA V1
Acura V1 is Volumetric pump with color display, suitable for critical care and general infusion applications. Flow rate starts from 0.1ml/hr & compatible with all brands of infusion sets.
Infusion Modes: Rate Mode, Time Mode, Weight Mode, Stage Mode, Drip Rate Mode.
Features
Color Display
High definition 3.2” Color TFT display with user friendly interface
Multiple Infusion Modes
In-built Flow rate, Time/volume, Dosage/Weight, Infusion modes
Double CPU
Double CPU ensures safety and reliability of infusion
Bolus Modes
Dual bolus: Automatic and Manual along with Anti-Bolus function.
Device Memory
2000 history records and last configuration memory
Accurate Infusion
Precise control of the infusion rate and volume with Particular stage infusion mode
Automatic IV Set Calibration
Calibrated for all standard IV Infusion sets
Pressure Detection
3 level occlusion sensitivities setting (programmable) with picture representation
Alarms
Audio and visual alarms for alerts
Fixing Clamp
Vertical & Horizontal rotatable fixation clamp
Technical Specifications
Display |
3.2 inch Color TFT (240X320 Pixels) |
IV Sets |
Standard IV sets of 20d/ml and 60d/ml, with diameter 3.4-4.5mm |
Infusion Modes |
Rate Mode, Time Mode, Drug/ Weight Mode, Drip Rate Mode(optional) |
Infusion Accuracy |
≤± 5 % (after calibration) |
Volume Limit |
1-9999 ml |
Flow Rate Range |
0.1 ml/hr-1200ml/hr (20d/ml IV set) |
0.1 ml/hr-1200ml/hr (20d/ml IV set) |
|
BOLUS |
Default 600ml/h, Values adjustable within 10-1200ml/hr (20d/ml IV set) |
Default 150ml/h ,Values adjustable within 10-150ml/hr (60d/ml IV set) |
|
BOLUS Accuracy |
≤± 5 % (after calibration) |
Purge Rate |
600ml/hr (20d/ml IV set) |
150ml/hr (60d/ml IV set) |
|
KVO |
0.1-10ml/hr (after infusion) |
Occlusion Level |
3-level Sensitivities Setting |
Bubble detection |
Ultrasonic with 3-level sensitivities setting, working frequency: 2MHz±5% |
Effective bubble detection volume:≥0.025ml |
|
Audio & Visual Alarm |
Door open, AIR in Line, Occlusion, No operation, Power OFF, Low Battery, Battery Err, Battery Lost, AC Lost, Sensor Err, Motor Err, Circuit Err.,COM. Err, Overflowing etc. |
Power Supply |
100V-240V AC,50Hz/60Hz |
Battery Type |
Internal rechargeable Ni-MH DC12V 2000mAh |
Battery Backup |
4 hours at 25ml/hr after fully recharged |
Classification |
Class I, CF, IPX2 |
Dimensions |
167mm(L) X 125mm(B) X 115mm(H) ( handgrip and clamp excluded) |
Weight |
1.8Kg Approx |
Operational Conditions |
Temperature: +5˚C - +40˚C |
Relative Humidity ≤80% |
|
Atmospheric Pressure 70KPa - 106Kpa |
|
Storage & Transportation Conditions |
Temperature: -22˚C - +55˚C |
Relative Humidity : 10% - 90% |
|
Atmospheric Pressure 70KPa - 106Kpa |