VPM 50 Patient Monitor
Feature
Technical Specification:
ECG:
Electrode |
3 or 5 Leads |
Display |
5 Waveforms with HR |
Lead |
I, II, III, aVR, aVL, aVF, V (5 Lead) I, II or III ( 3 Lead) |
Gain Selection |
x1/4, x1/2, x1 and x2 |
Frequency Response |
Diagnostic: 0.05 to 90 Hz |
Calibration Signal |
1(mV p-p), Accuracy: +5% |
ECG Signal Range |
±8 m V (Vp -p) |
Pulse Oximetry:
Range |
0 to 100% |
Resolution |
1% |
Accuracy |
70% to 99% range ±2% / 0 to 69%, undefined |
Methode |
Dual wavelength LED |
Nibp:
Technique |
Oscillometric during inflation |
Range |
Adult: 40-270 mm Hg |
Measurement Cycle |
<40 sec, typical |
Cycles (Selectable) |
2,3,5,10,15,30 min1,2,4 hr |
Max. Allowable Cuff Pressure |
Adult: 297±3 mm Hg |
Resolution |
1 mm Hg |
Transducer Accuracy |
±2 mm Hg or ±2% of reading |
Temperature (2 Channel):
Range, Accuracy |
0 - 50˚C + 0.1˚C |
Display Resolution |
±0.1˚C |
Probe |
YSI 400 AND YSI 700 Series |
Respiration Rate:
Rate |
Adult : 0 ~ 120 rpm |
Resolution |
1 rpm |
Accuracy |
±2 breath / min |
Heart (Pulse) Rate:
Source |
User Selectable : Smart, ECG, Plinth, Nibp |
Range |
Adult 15-300 bpm |
Accuracy |
±1 bpm or ±1 % |
Environment:
Operating Temperature |
59˚ - 95˚F (15˚ - 35˚C) |
Storage Temperature |
23˚ - 122˚F (-5˚ - 50˚C) |
Humidity |
15% to 90% |
Trends:
Memory |
96 Hr at 30 seconds intervals for a NIBP reading every 5 minutes |
Display |
Trabular, graphical |
General:
Dimensions |
200 (L) x 100 (B) x 200 (T) mm |
Weight |
1.5 Kg |
Power |
AC 100-240 V , 50/60 Hz |
Power Consumption |
35 W |
Battery |
14.8 V / 2200 Mah Li-Ion |
Recharge Time |
4.5 hours |
Operating Time |
3 Hours typical |
Standard Accessories:
Finger Probe |
1 No |
Mains Cable |
1 No |
Cuff (Adult) |
1 No |
5 Lead ECG Cable |
1 No |
Temperature Probe |
1 No |
Estimated Delivery Time:_5 to 7 Working Days
VARIANT | SELLER | PRICE | QUANTITY |
---|
Brand | MAESTROS ELECTRONICS |
VPM 50 Patient Monitor
Feature
Technical Specification:
ECG:
Electrode |
3 or 5 Leads |
Display |
5 Waveforms with HR |
Lead |
I, II, III, aVR, aVL, aVF, V (5 Lead) I, II or III ( 3 Lead) |
Gain Selection |
x1/4, x1/2, x1 and x2 |
Frequency Response |
Diagnostic: 0.05 to 90 Hz |
Calibration Signal |
1(mV p-p), Accuracy: +5% |
ECG Signal Range |
±8 m V (Vp -p) |
Pulse Oximetry:
Range |
0 to 100% |
Resolution |
1% |
Accuracy |
70% to 99% range ±2% / 0 to 69%, undefined |
Methode |
Dual wavelength LED |
Nibp:
Technique |
Oscillometric during inflation |
Range |
Adult: 40-270 mm Hg |
Measurement Cycle |
<40 sec, typical |
Cycles (Selectable) |
2,3,5,10,15,30 min1,2,4 hr |
Max. Allowable Cuff Pressure |
Adult: 297±3 mm Hg |
Resolution |
1 mm Hg |
Transducer Accuracy |
±2 mm Hg or ±2% of reading |
Temperature (2 Channel):
Range, Accuracy |
0 - 50˚C + 0.1˚C |
Display Resolution |
±0.1˚C |
Probe |
YSI 400 AND YSI 700 Series |
Respiration Rate:
Rate |
Adult : 0 ~ 120 rpm |
Resolution |
1 rpm |
Accuracy |
±2 breath / min |
Heart (Pulse) Rate:
Source |
User Selectable : Smart, ECG, Plinth, Nibp |
Range |
Adult 15-300 bpm |
Accuracy |
±1 bpm or ±1 % |
Environment:
Operating Temperature |
59˚ - 95˚F (15˚ - 35˚C) |
Storage Temperature |
23˚ - 122˚F (-5˚ - 50˚C) |
Humidity |
15% to 90% |
Trends:
Memory |
96 Hr at 30 seconds intervals for a NIBP reading every 5 minutes |
Display |
Trabular, graphical |
General:
Dimensions |
200 (L) x 100 (B) x 200 (T) mm |
Weight |
1.5 Kg |
Power |
AC 100-240 V , 50/60 Hz |
Power Consumption |
35 W |
Battery |
14.8 V / 2200 Mah Li-Ion |
Recharge Time |
4.5 hours |
Operating Time |
3 Hours typical |
Standard Accessories:
Finger Probe |
1 No |
Mains Cable |
1 No |
Cuff (Adult) |
1 No |
5 Lead ECG Cable |
1 No |
Temperature Probe |
1 No |